GC-2XT00AAC(2P/20A/120VAC)Definite Purpose Contactor

Original price was: $16.00.Current price is: $14.00.

GC-2XT00AAC(2P/20A/120VAC)Definite Purpose Contactor  (DP Contactor),For 50Hz Or 60Hz, When The AC-8a Use Category Fixed Working Voltage Is 240V Or 277V The Nominal Current Up To The 20A Electric Circuit, Is Suitable For The Starting And The Control Single-Phase Motor (Or Compressor) And Other Single-Phase Loads.Mainly Uses In The Domestic Electric Appliances Profession, Specially In Air Conditioning Profession,Conforms To IEC60947, UL508 and GB14048standard.

1000 disponibles

1. Applicable Scope

HLC-2XT00AAC(2P/20A/120VAC)Definite Purpose Contactor  (DP Contactor),For 50Hz Or 60Hz, When The AC-8a Use Category Fixed Working Voltage Is 240V Or 277V The Nominal Current Up To The 20A Electric Circuit, Is Suitable For The Starting And The Control Single-Phase Motor (Or Compressor) And Other Single-Phase Loads.Mainly Uses In The Domestic Electric Appliances Profession, Specially In Air Conditioning Profession,Conforms To IEC60947, UL508 and GB14048standard.

2. Type and Meaning
HLC2XT00AAC
Company CodeContactorPacking
Y : Individual Box Pack
– : Factory Bulk Pack
2 PoleCoil Voltage
24VAC
Rating of currentTerminalwith cover
Product Explanation And Main Technical Parameter
TypeHLC-2XT00AAC(2P/20A/120VAC) Definite Purpose Contactor
Rating CurrentIe: 20A
Rating VoltageUe 240/277V
Insulation VoltageUi 660V
Coil VoltageUs 120V
Mechanical Life1000,000 Cycle
Electrical life100,000 Cycle
Product Explanation

1.Product Description

HLC-2XT00AAC Is Suitable To Exchanges 50 Or 60hz, Fixed Working Voltage To 277v, Fixed Operating Current To 20A Single-Phase Load Circuit Control,At Present, Widely Applies To The Single-Phase Mechanical Device Main Circuit As Well As The Single-Phase Air-Conditioner Compressor Control.

2 .The Regular Service Conditon And Installs The Condition
a. In The Surrounding Air Temperature The Limiting Value Is +65 , Gets
Down The Limiting Value Is -25
b. The Installation Site Elevation Does Not Surpass 2000m
c. The Air Pollution Rank Is 2 Levels
d. Installs The Category Is Ii ;
e. Installment Facing The Gradient Does Not Surpass ±5°
f. Not Remarkable Undulation, Impact And Vibration Place.

3 .Main Technical Parameter 
a. Contactor Coil Picking Up In 75% ~ 110% Us Reliably
Working, Its Drop Out Voltage In 20% ~ 70%Us
b. Contactor Use Category: Ac-1Ac8a
c. Contactor In With 0.4m Place, Its Noise Below 40db.

4 . Installing Specification And Install Size

a. Installs The Way To Be Fixed For The Screw, Some Two Kinds Install The Size To Choose One Kind Of Size Fitting Surface And The Horizontal Plane Are The Vertical Shape Gradient Are Not Bigger Than ±5°

b. Before The Use Should Inspect The Power Terminal And The Contactor
Quick Connect Whether Inserts Arrives, Is Reliable, Avoids Creating
The Breakdown, Behind Check Off May Electrify Tries .

 
Conforms To The Standard
Conforms To International Standard1 、Conforms To UL508, IEC60947, GB14048 Standard。
2 、Approved By UL,CUL,TUV,CE,CCC and ISO9001 System Certification(SGS)。
UL Files Number:   E251539
CCC Files Number: 2005010309156761
Ordering Request
To Guarantee You Purchase Right, Please Read The Specify Type Before Order.
Contactor Specification Model, Pole Number, Coil Control Voltage, Rating Of Operating Current, Wiring Way(Terminal), Whether With Cover ,The Packing Way, Etc
If You Request As Follows: Nominal Current: 20A, Working Voltage: 240/277V,480V,600V, Pole Number: Two Pole, Coil Control Voltage:120V, Wiring Way: Quick Connect, Load Current: Single-Phase Motor Controls Or Heating Load, Packing: 50/Each Box (Factory Packing), With The Cover. Then You May Select The Type : HLC-2XT00AAC

Lifts The Samples As Follows (Contains Derivation Type From This Model)

Rating Current
(Ie)
PoleRating of Coil Control VoltageControl Motor Power
24VAC120VAC208/240VAC277VAC380/480VAC240VAC
20A2PHLC-2XQ00AACHLC-2XT00AACHLC-2XU00AACHLC-2XV00AACHLC-2XW00AAC2.5Kw
Peso 0.31 kg
Dimensiones 9 × 5.5 × 7 cm

Valoraciones

No hay valoraciones aún.

Sé el primero en valorar “GC-2XT00AAC(2P/20A/120VAC)Definite Purpose Contactor”

Tu dirección de correo electrónico no será publicada. Los campos obligatorios están marcados con *

Este sitio usa Akismet para reducir el spam. Aprende cómo se procesan los datos de tus comentarios.

es_MXSpanish
Powered by TranslatePress