HLC-3XT02CY(3P/30A/120VAC) Definite Purpose Contactor

Original price was: $21.00.Current price is: $19.00.

HLC-3XT02CY(3P/30A/120VAC)Definite Purpose Contactor (DP Contactor),Mainly Is Suitable For 50Hz Or 60Hz, When The AC-8a Use Category Fixed Working Voltage Is 277V Or 600V The Nominal Current Up To The 30A Electric Circuit, Is Suitable For The Starting And The Control Three-Phase Motor (Or Compressor) And Other Three-Phase Loads.Mainly Uses In The Domestic Electric Appliances Profession, Specially In Air Conditioning Profession,Conforms To IEC60947, UL508 and GB14048standard.

500 disponibles

Applicable and Description

1. Applicable Scope

HLC-3XT02CY(3P/30A/120VAC)Definite Purpose Contactor (DP Contactor),Mainly Is Suitable For 50Hz Or 60Hz, When The AC-8a Use Category Fixed Working Voltage Is 277V Or 600V The Nominal Current Up To The 30A Electric Circuit, Is Suitable For The Starting And The Control Three-Phase Motor (Or Compressor) And Other Three-Phase Loads.Mainly Uses In The Domestic Electric Appliances Profession, Specially In Air Conditioning Profession,Conforms To IEC60947, UL508 and GB14048standard.

2. Type and Meaning
HLC3XT02CY
Company CodeContactorPacking
Y : Individual Box Pack
– : Factory Bulk Pack
3 PoleCoil Voltage
120VAC
Rating of current#10-32 Combo screw with dual QC
Product Explanation And Main Technical Parameter
Type
HLC-3XT02CY(3P/30A/120VAC) Definite Purpose Contactor
Rating CurrentIe: 30A
Rating VoltageUe: 240/277V
Insulation VoltageUi: 660V
Coil VoltageUs: 120V
Mechanical Life1000,000 Cycle
Electrical life100,000 Cycle
Product Explanation

1.Product Description

HLC-3XT02CY is Suitable To Exchanges 50 Or 60hz, Fixed Working Voltage To 600v, Fixed Operating Current To 20A Three-Phase Load Circuit Control,At Present, Widely Applies To The Three-Phase Mechanical Device Main Circuit As Well As The Three-Phase Air-Conditioner Compressor Control.

2 .The Regular Service Conditon And Installs The Condition
a. In The Surrounding Air Temperature The Limiting Value Is +65 , Gets
Down The Limiting Value Is -25
b. The Installation Site Elevation Does Not Surpass 2000m
c. The Air Pollution Rank Is 2 Levels
d. Installs The Category Is Ii ;
e. Installment Facing The Gradient Does Not Surpass ±5°
f. Not Remarkable Undulation, Impact And Vibration Place.

3 .Main Technical Parameter
a. Contactor Coil Picking Up In 75% ~ 110% Us Reliably
Working, Its Drop Out Voltage In 20% ~ 70%Us
b. Contactor Use Category: Ac-1Ac8a
c. Contactor In With 0.4m Place, Its Noise Below 40db.

4 . Installing Specification And Install Size

a. Installs The Way To Be Fixed For The Screw, Some Two Kinds Install The Size To Choose One Kind Of Size Fitting Surface And The Horizontal Plane Are The Vertical Shape Gradient Are Not Bigger Than ±5°

b. Before The Use Should Inspect The Power Terminal And The Contactor
Quick Connect Whether Inserts Arrives, Is Reliable, Avoids Creating
The Breakdown, Behind Check Off May Electrify Tries .

 
Conforms To The Standard
Conforms To International Standard1 、Conforms To UL508, IEC60947, GB14048 Standard。
2 、Approved By UL,CUL,TUV,CE,CCC and ISO9001 System Certification(SGS)。
UL Files Number:   E251539
CCC Files Number: 2005010309156761
Ordering Request
To Guarantee You Purchase Right, Please Read The Specify Type Before Order.
Contactor Specification Model, Pole Number, Coil Control Voltage, Rating Of Operating Current, Wiring Way(Terminal), Whether With Cover ,The Packing Way, Etc
If You Request As Follows: Nominal Current: 30A, Working Voltage: 240/277V,480V,600V, Pole Number: Three Pole Without Shunt, Coil Control Voltage:120V, Wiring Way: Quick Connect, Load Current: Three-Phase Motor Controls Or Heating Load, Packing: 25/Each Box (Factory Packing), With The Cover. Then You May Be Elect The Type : HLC-3XT02CY

Lifts The Samples As Follows (Contains Derivation Type From This Model)

Rating Current
(Ie)
PoleRating of Coil Control VoltageControl Motor Power
24VAC120VAC208/240VAC277VAC400VAC240VAC
30A3PHLC-3XQ02CYHLC-3XT02CYHLC-3XU02CYHLC-3XV02CYHLC-3XH02CY7.5Kw
Peso 0.48 kg
Dimensiones 10 × 6.5 × 8 cm

Valoraciones

No hay valoraciones aún.

Sé el primero en valorar “HLC-3XT02CY(3P/30A/120VAC) Definite Purpose Contactor”

Tu dirección de correo electrónico no será publicada. Los campos obligatorios están marcados con *

Este sitio usa Akismet para reducir el spam. Aprende cómo se procesan los datos de tus comentarios.

es_MXSpanish
Powered by TranslatePress